按裝特(te)殊要(yao)求:
1、跟據一體式化廢水解決設施(shi)安(an)(an)裝(zhuang)(zhuang)程(cheng)序(xu)使(shi)(shi)用(yong)(yong)圖與基(ji)本(ben)(ben)條(tiao)件(jian)圖,做(zuo)到位(wei)準備基(ji)本(ben)(ben)條(tiao)件(jian)以安(an)(an)裝(zhuang)(zhuang)程(cheng)序(xu)使(shi)(shi)用(yong)(yong)水總平面圖的大小(xiao)(xiao)大小(xiao)(xiao)來算(suan),做(zuo)到位(wei)混(hun)泥土(tu)(tu)土(tu)(tu)底板,基(ji)本(ben)(ben)條(tiao)件(jian)規范(fan)要求平均(jun)的耐壓5t/m2,基(ji)本(ben)(ben)條(tiao)件(jian)應該情況,并應在(zai)混(hun)泥土(tu)(tu)土(tu)(tu)基(ji)本(ben)(ben)條(tiao)件(jian)澆鑄檢修期收場(chang)后性能(neng)展開安(an)(an)裝(zhuang)(zhuang)程(cheng)序(xu)使(shi)(shi)用(yong)(yong),如設施(shi)安(an)(an)裝(zhuang)(zhuang)程(cheng)序(xu)使(shi)(shi)用(yong)(yong)在(zai)地坪下述,基(ji)本(ben)(ben)條(tiao)件(jian)離(li)地坪比(bi)標高按圖大小(xiao)(xiao)來算(suan),并且4周搜集整理大小(xiao)(xiao),寬度應該離(li)基(ji)本(ben)(ben)條(tiao)件(jian)邊線500mm這(zhe)些,能(neng)夠(gou)管網安(an)(an)裝(zhuang)(zhuang)程(cheng)序(xu)使(shi)(shi)用(yong)(yong)。
2、地(di)埋(mai)管的按(an)照(zhao)無線連(lian)接應(ying)該在機(ji)(ji) 各就(jiu)各位(wei)時(shi)選(xuan)擇(ze)好,機(ji)(ji) 各就(jiu)各位(wei)時(shi)應(ying)該按(an)闡明書(shu)機(ji)(ji) 自身重量,匹(pi)配(pei)履帶吊總噸位(wei)數(shu)值,的按(an)照(zhao)先后順序按(an)場地(di)差表圖各就(jiu)各位(wei),鍋筒的地(di)段,中心點不會放錯,雙方安全距(ju)離應(ying)該規范
3、按照(zhao)裝配圖,鏈接通道(dao),生產(chan)設備(bei)準備(bei)就緒后鏈接通道(dao)用鉛筆墊鎖緊好,使(shi)鏈接處不滲漏。
4、地埋式污(wu)廢水解決設(she)(she)(she)(she)(she)施(shi)(shi)(shi)裝有及時(shi)后設(she)(she)(she)(she)(she)施(shi)(shi)(shi)與根本實木地板要(yao)(yao)進行連接(jie)不變,絕 對衡量不使設(she)(she)(she)(she)(she)施(shi)(shi)(shi)變化上浮, 同時(shi)須在設(she)(she)(she)(she)(she)施(shi)(shi)(shi)中注射到污(wu)廢水(無污(wu)廢水時(shi),用(yong)某些水或杭州自來(lai)水用(yong)于),保持度要(yao)(yao)達成70%這些,當心設(she)(she)(she)(she)(she)施(shi)(shi)(shi)上浮。同時(shi),觀察好各(ge)管(guan)道鋪(pu)設(she)(she)(she)(she)(she)有滲漏。通水各(ge)管(guan)路口處要(yao)(yao)不滲漏,同時(shi)設(she)(she)(she)(she)(she)施(shi)(shi)(shi)不主房(fang)屋(wu)地面水回升(sheng),而使設(she)(she)(she)(she)(she)施(shi)(shi)(shi)不齊和偏移(yi)。
5、機械(xie)儀器裝(zhuang)結束以后無(wu)不(bu)正確后,必須用土(tu)填上機械(xie)儀器四個星期(qi)與(yu)寬度(du)中(zhong)增強(qiang),并整平房(fang)屋地(di)面填土(tu)的時(shi)候應該(gai)留意:
(1)機 人孔檔板須(xu)要高了地坪50mm范圍(wei);
(2)沒辦(ban)法讓土(tu)短路人孔堵蓋(gai)上(shang)的進氣口。
6、把電子管(guan)(guan)控(kong)(kong)(kong)系統柜(ju)(ju)管(guan)(guan)控(kong)(kong)(kong)線與(yu)設備無法(fa)接(jie)通(tong),插頭接(jie)線兩(liang)端處時(shi)關注海(hai)下爆(bao)氣機及潛污泵無刷電機的轉為,如地(di)底(di)室管(guan)(guan)控(kong)(kong)(kong)柜(ju)(ju)要在(zai)透氣處,恢復烘(hong)干,尋常管(guan)(guan)控(kong)(kong)(kong)柜(ju)(ju)沒辦(ban)法(fa)在(zai)暴露出來(lai)。須防(fang)曝曬,淋雨等。容易管(guan)(guan)控(kong)(kong)(kong)板及插頭接(jie)線兩(liang)端處頭漏電,損毀管(guan)(guan)控(kong)(kong)(kong)板。
7、地(di)埋式污泥治理裝備需(xu)要注(zhu)意作用:
(1)機器設(she)備裝(zhuang)置(zhi)的地方一定要確保下雨了不的積水情況(kuang);
(2)設施設備的(de)出(chu)液管要在(zai)對地坪0.4m一下(xia);
(3)機(ji)械設備(bei)頂端允(yun)許(xu)壓有高(gao)空墜落,允(yun)許(xu)有大形行(xing)駛通(tong)過(指無層次性設置的);
(4)生產(chan)設(she)施設(she)備一樣(yang) 不(bu)容許(xu)抽時間內外污水滲漏(lou),以制(zhi)止(zhi)地埋(mai)水把(ba)生產(chan)設(she)施設(she)備浮起。
8、要留意本(ben)機械設備安(an)裝(zhuang)圖(tu)及管(guan)道鋪設連(lian)入(ru)(ru)圖(tu)按特殊要求連(lian)入(ru)(ru)及平面磨擺設,如觀眾特殊要求可隨意擺設,但就必須在訂紙質合同時入(ru)(ru)憲(xian)。
9、接好通風機電機、抽水機保持路線圖,并關注通風機電機、抽水機的轉到要恰當準確無誤。